Infrared Zoom Lens Parameters
Product Name | Infrared Lens |
Focal Length | 25-75mm |
F# | 1.2 |
Wavelength | 8-14um |
Detector | 640x512-17um / 640x512-12um |
Image Diagonal | 14mm |
Average Transmission | >80%(For DLC) / >87%(For AR) |
Circular FOV | (H)25°x(V)20°x(D)31° / (H)8.3°x(V)6.6°x(D)10.6° |
Dimensions | 125mm / 120mm |
Focus Type | Motorized Lens |
Focus Range | 1m to infinity |
Mount Type | M34x0.75-6g |
Weight | 737g |
Operating Temperature | -40℃~+80℃ |
Storage Temperature | -40℃~+80℃ |
External Coating | DLC / AR Coating |
Manufacturing Technique:
1. Inner carving test platform;
2. Microscope;
3. Opto Tech aspheric processing;
4. Polishing machine;
5. Thickness Gauge;
6. Ultrasonic Cleaner;
7. Workshop;
8. Interferometer;
9. High and low tempera ture test chamber;
10. High polishing machine;
11. Optical bench;
12. Raul milling;
13. Atomic force microscope;
14. Centralinstrument;
15. Hand Grinding and Polishing Machine;
FAQ:
Why cannot the lens control board or module connect to the computer?
There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:
1. Replace the USB port, which may be incompatible with the data cable;
2. Replace the data cable,maybe the data cable is not compatible with the computer or the cable data is wrongly selected;
3. Confirm the wiring of the module or the control board, maybe the wiring is loose;
4. Module or control board hardware problem, replace the hardware.
LWIR Zoom Lens Description
Wavelength: 8-14um Wavelength
Features: Continuous zoom
Apply to: 640x512-17um and 640x512-12um Detector.
Zoom lenses can be classified according to focal length, focal length value, aperture and zoom function.
1. Lenses can be categorized by focal length, which may vary and may have an automatic or manual aperture, among other features.
2. The classification of lenses is divided according to the size of the focal length, such as ordinary, wide-angle, telephoto and so on.
3. The lens zoom mechanism can be manual, electric and other options.
Infrared Zoom Lens Parameters
Product Name | Infrared Lens |
Focal Length | 25-75mm |
F# | 1.2 |
Wavelength | 8-14um |
Detector | 640x512-17um / 640x512-12um |
Image Diagonal | 14mm |
Average Transmission | >80%(For DLC) / >87%(For AR) |
Circular FOV | (H)25°x(V)20°x(D)31° / (H)8.3°x(V)6.6°x(D)10.6° |
Dimensions | 125mm / 120mm |
Focus Type | Motorized Lens |
Focus Range | 1m to infinity |
Mount Type | M34x0.75-6g |
Weight | 737g |
Operating Temperature | -40℃~+80℃ |
Storage Temperature | -40℃~+80℃ |
External Coating | DLC / AR Coating |
Manufacturing Technique:
1. Inner carving test platform;
2. Microscope;
3. Opto Tech aspheric processing;
4. Polishing machine;
5. Thickness Gauge;
6. Ultrasonic Cleaner;
7. Workshop;
8. Interferometer;
9. High and low tempera ture test chamber;
10. High polishing machine;
11. Optical bench;
12. Raul milling;
13. Atomic force microscope;
14. Centralinstrument;
15. Hand Grinding and Polishing Machine;
FAQ:
Why cannot the lens control board or module connect to the computer?
There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:
1. Replace the USB port, which may be incompatible with the data cable;
2. Replace the data cable,maybe the data cable is not compatible with the computer or the cable data is wrongly selected;
3. Confirm the wiring of the module or the control board, maybe the wiring is loose;
4. Module or control board hardware problem, replace the hardware.